Aquastat Relay, 180 – 240 F Range with 15 Degree F Fixed Differential

Price
Request a Quote
Stock
In Stock

Specifications

Hazmat Information

  • UN 1294, TOLUENE, 3, II

Dimensions

  • 6-1/8 in. high x 4-5/16 in. wide x 3-1/8 in. deep
  • 156 mm high x 110 mm wide x 79 mm deep

Maximum Safe Operating Pressure

  • Immersion Well: 255 psi
  • Immersion Well: 1757 kPa

Temperature Range

  • Maximum: 150 °F with 1.2 A 24 V load; 77 °F with 1.4 A 24 V load
  • Maximum: 66 °C with 1.2 A 24 V load; 25 °C with 1.4 A 24 V load

Includes

  • Molex® plug for use with vent damper, includes heat-conductive compound.; Molex(r) plug for use with vent damper, includes heat-conductive compound.

Mounting

  • Vertical Mount

Electrical Ratings

  • Low Voltage: 0.8 A max. @ 24 Vac; 0.25 A @ 0.25 to 12 Vdc; At Locked Rotor - 44.4A @ 120 Vac: 22.2A @ 240 Vac

Frequency

  • 60 Hz

Approvals, Underwriters Laboratories Inc.

  • UL Listed: File No. MP466, Vol. 13, Sec. 2, Guide No. MBPR2.

Approvals, Canadian Standards Association

  • Certified: File No. LR95329-1

Tradeline Value

  • Tradeline

Electrical Connections

  • Quick-Connect / Screw

Operating Humidity Range

  • 0 to 95% RH, non-condensing

Voltage

  • 120 Vac

Operating Temperature Range

  • High Limit: 180 °F to 240 °F
  • High Limit: 82 °C to 116 °C

Differential Temperature

  • 15 °F fixed

Switching Action

  • SPST: High Limit & Circulator

Anticipator Setting

  • 0.2 A

Capillary Length

  • 4-1/2 in.
  • 114 mm

Insulation Depth

  • 1-1/2 in. to 3 in. less well
  • 38 mm to 76 mm less well

Electrical Ratings, Burner

  • At Full Load - Low Voltage: 0.8 A max. @ 24 Vac: Line Voltage: 7.4 A @ 120 Vac: 3.7 A @ 240 Vac; At Locked Rotor - Line Voltage: 44.4 A @ 120 Vac: 22.7 A @ 240 Vac

Electrical Ratings, Circulator

  • At Full Load - 7.4 A @ 120 Vac: 3.7 A @ 240 Vac; At Locked Rotor - 44.4 A @ 120 Vac: 22.2 A @ 240 Vac

Similar SKUs

L4006A1967/U
L4006A1967/U
L4006A1967/U Aquastat, Breaks on Rise, 100-240F Range, 240F Factory Stop, 5-30F Adjustable Differential
Resideo Technologies
Request a Quote
In Stock
Aquastat, Breaks on Rise, 100-240F Range, 240F Factory Stop, 5-30F Adjustable Differential
L4008A1015/U
L4008A1015/U
L4008A1015 High or Low Limit Aquastat® Controller
Resideo Technologies
Request a Quote
In Stock
High or Low Limit Aquastat, 100F – 240F, 66” Capillary, 5F to 30F Adj Differential
L8124A1007/U
L8124A1007/U
L8124A1007/U Triple Aquastat Relay for Oil Applications, Vertical Case, 1.5" Insulation Depth
Resideo Technologies
Request a Quote
In Stock
Triple Aquastat Relay for Oil Applications, Vertical Case, 1.5" Insulation Depth
L8124C1003/U
L8124C1003/U
L8124C1003/U Triple Aquastat Relay for Oil Applications, Horizontal Case, 1.5" Insulation Depth
Resideo Technologies
Request a Quote
In Stock
Triple Aquastat Relay for Oil Applications, Horizontal Case, 1.5" Insulation Depth
L8124E1016/U
L8124E1016/U
L8124E1016/U High Limit Protection, Low Limit and Circulation Control Triple Aquastat Relay
Resideo Technologies
Request a Quote
In Stock
High Limit Protection, Low Limit and Circulation Control Triple Aquastat Relay
L8124L1011/U
L8124L1011/U
L8124L1011/U Triple Aquastat Relay with High Limit
Resideo Technologies
Request a Quote
In Stock
Triple Aquastat Relay with High Limit
L8148A1017/U
L8148A1017/U
L8148A1017/U Aquastat Relay, 140 – 240 F Range with 8 Degree F Fixed Differential, Low Volt/Millivolt
Resideo Technologies
Request a Quote
In Stock
Aquastat Relay, 140 – 240 F Range with 8 Degree F Fixed Differential, Low Volt/Millivolt
L8148J1009/U
L8148J1009/U
L8148J1009/U Aquastat Relay, 120 – 240 °F Range with 8 °F Fixed Differential, Low Volt/Millivolt
Resideo Technologies
Request a Quote
In Stock
Aquastat Relay, 120 – 240 F Range with 8 Degree F Fixed Differential, Low Volt/Millivolt
show more