High Limit Protection, Low Limit and Circulation Control Triple Aquastat Relay

Price
Request a Quote
Stock
In Stock
Does not ship to VA, United States

Specifications

Hazmat Information

  • UN 1294, TOLUENE, 3, II

Dimensions

  • 6-1/8 in. high x 4-3/8 in. wide x 3-1/16 in. deep
  • 156 mm high x 111 mm wide x 78 mm deep

Maximum Safe Operating Pressure

  • 200 psi on outside of immersion well, 100 psi on capsule if inserted directly.
  • 1378 kPa on outside of immersion well, 690 kPa on capsule if inserted directly.

Temperature Range

  • -30 °F to 150 °F at switches; 265 °F at sensing element
  • -34 °C to 66 °C at switches; 129 °C at sensing element

Mounting

  • Vertical Mount

Frequency

  • 60 Hz

Electrical Connections

  • Quick-Connect / Screw

Operating Humidity Range

  • 0 to 95% RH, non-condensing

Voltage

  • 120 Vac

Operating Temperature Range

  • High Limit: 130 °F to 240 °F; Low Limit: 110 °F to 220 °F
  • High Limit: 54 °C to 116 °C; Low Limit: 43 °C to 104 °C

Differential Temperature

  • High limit: 10 °F fixed; low limit: 10 to 25 °F adj.

Switching Action

  • SPST: High & Low Limit

Electrical Ratings, Burner

  • 1.25A at 24 Vac; 30 VA (total load) Terminals B1-B2 and TV-Z

Electrical Ratings, Circulator

  • At Full Load - 7.4 A @ 120 Vac: 3.7 A @ 240 Vac; At Locked Rotor - 44.4 A @ 120 Vac: 22.2 A @ 240 Vac

Similar SKUs

L4008A1015/U
L4008A1015/U
L4008A1015 High or Low Limit Aquastat® Controller
Resideo Technologies
Request a Quote
In Stock
High or Low Limit Aquastat, 100F – 240F, 66” Capillary, 5F to 30F Adj Differential
L4008E1156/U
L4008E1156/U
L4008E1156/U High Limit Manual Reset Aquastat, 130F – 270F, 66 in Capillary, Factory Stop at 250F
Resideo Technologies
Request a Quote
In Stock
High Limit Manual Reset Aquastat, 130F – 270F, 66 in Capillary, Factory Stop at 250F
L6006A1145/U
L6006A1145/U
L6006A1145/U High or Low Limit Horizontal Mount Controller with SPDT, Operating Range 100-240F, 3" Capillary
Resideo Technologies
Request a Quote
In Stock
High or Low Limit Horizontal Mount Controller with SPDT, Operating Range 100-240F, 3" Capillary
L6006C1018/U
L6006C1018/U
L6006C1018/U High or Low Limit Surface Mount Controller with SPDT, Operating Range 65-200F, Factory Stop at 200F
Resideo Technologies
Request a Quote
In Stock
High or Low Limit Surface Mount Controller with SPDT, Operating Range 65-200F, Factory Stop at 200F
L8124A1007/U
L8124A1007/U
L8124A1007/U Triple Aquastat Relay for Oil Applications, Vertical Case, 1.5" Insulation Depth
Resideo Technologies
Request a Quote
In Stock
Triple Aquastat Relay for Oil Applications, Vertical Case, 1.5" Insulation Depth
L8124C1003/U
L8124C1003/U
L8124C1003/U Triple Aquastat Relay for Oil Applications, Horizontal Case, 1.5" Insulation Depth
Resideo Technologies
Request a Quote
In Stock
Triple Aquastat Relay for Oil Applications, Horizontal Case, 1.5" Insulation Depth
L8124L1011/U
L8124L1011/U
L8124L1011/U Triple Aquastat Relay with High Limit
Resideo Technologies
Request a Quote
In Stock
Triple Aquastat Relay with High Limit
L8148E1265/U
L8148E1265/U
L8148E1265/U Aquastat Relay, 180 – 240 °F Range with 15 Degree °F Fixed Differential
Resideo Technologies
Request a Quote
In Stock
Aquastat Relay, 180 – 240 F Range with 15 Degree F Fixed Differential
show more