10 & 15 Sec. TFI Non-Recycle, 30 Sec. Purge EP Programmer Module
The Fireye EP Programmer modules are used with the E100 and E110 Flame-Monitor controls. They provide start-up programming, safe-start-check, and flame monitoring supervision. They prove high-fire purge interlock (EP100 series only), low-fire start position and fuel valve end-switch safety checks. A running interlock circuit monitors the limit switches, air flow switches and fuel pressure switches.
The EP programmers de-energize all fuel valve circuits with 4 seconds (max.) following a flame failure (2 seconds for the EP165, EP166, EP265), or at the end of the pilot-trial-for ignition period if no flame is detected. A modulator motor circuit is provided (EP100 and EP200 series only). The programmers have a Check-Run switch to stop the control sequence to aid in the set-up and check out of the burner and its associated interlocks. The programmers store the burner cycles, hours and lockout history.
The EP programmers offer the following selectable unctinos: purge timing, prove the Running Interlock circuit is open at the start of the cycle, recycle or non-recycle operation (EP300 series only), intermittent or interrupted operation of terminal 6 (EP300 series only). The programmers include an RJ45 connector for the ED510 display module, and two RJ12 connectors for Modbus Communications.
EP260 Fireye Programmer Module, 30 Sec Pre-purge, 10 Sec PTFI, 10/15 MTFI, 4 Sec FFRT
PROGRAMMER MODULE
WITH SELECTABLE OPERATION
FOR USE WITH THE
FIREYE FLAME-MONITOR™ CONTROL
EP270 Fireye Programmer Module, 30 Sec Pre-purge, 5/10 Sec PTFI, 10 MTFI, 4 Sec FFRT

- CH MODE: 125 MBH
- CH MODE MIN: 22 MBH
- HEATING CAPACITY 113 MBH
- 95% AFUE
- 4"/2" CONCENTRIC PIPING, 2',3" POLYPRO, OR 3" CPVC
- GAS CONNECTION 3/4"
- SUPPLY/RETURN BOILER: 11/4" COPPER SWEAT (INCLUDES "LABOR SAVER" MANIFOLD)
UTICA CONDENSING HEAT ONLY
FLOOR MOUNTED BOILER (Floor Mount Stand)
125,000 BTU INPUT
113,000 BTU HEATING CAPACITY
22,000 BTU MINIMUM
95% AFUE.
The Flame-Monitor Series provides the proper burner sequencing, ignition and flame monitoring protection on automatically ignited oil, gas and combination fuel burners. On a safety shutdown, the display module will advise the operator that the control is in "Lockout" and indicate the cause as well as the position in the operating sequence that it occurred.
Interchangeable programmer and flame amplifier modules allow complete versatility in selecting control function. The Flame-Monitor control uses the same wiring base as the Fireye D-Series and C-Series Controls and is directly interchangeable with most models without rewiring.
The Flame-Monitor control can be used with ultraviolet, AUTOCHECK infrared, photocell, flame rod or self-check ultraviolet flame scanners by choosing the proper amplifier module. Special features include: remote reset, remote display, expanded annunciation of safety lockouts, programmability of safety interlock messages, and remote data communications capability. A 220 volt version of the E110 control is also available without any agency approvals. (P/N E120).