CARLIN OIL PRIMARY CONTROLS
Does not ship to OH, United States
Description
CARLIN OIL BURNER PRIMARY CONTROL 120V
Inventory
Displaying prices & availability for Ohio, United States 43201 in USD. Change location.
Models matching criteria: 6

 4 In Stock 

 OIL BURNER PRIMARY 0-Pre-Purge/0-Post-Purge 15 OR 45 SEC TFI view more 
- OIL BURNER PRIMARY
- NO PRE-PURGE
- NO POST-PURGE
- 15 OR 45 SECOND TRIAL FOR IGNITION
- Intermittent Duty Ignition
- Red LED Lockout Indicator
- Thermostat/aquastat Compatible SMC (Safety Monitoring Circuit) Technology
- Power Input (From Limit Circuit) 120 vac, 60 Hz, 10 VA Motor Load 5 FLA/60 LRA Ignitor Load 120 vac, 60 Hz, 500 VA
- Operating Temperature Limits + 32°F to + 140°F
- Storage Temperature Limits -40°F to +185°F
- Thermostat Anticipator Current 0.2 A, AC Cad Cell Resistance with Flame R < 1500 OHMS
48245 E Series Oil Primary Control (Optional 15 or 45 Sec. TFI. Constant/Intermittent Duty with Smart Ignition) Direct replacement for 3-wire primary controls (ex. Honeywell R8184G4009)
Does not ship to OH, United States
 8 In Stock 

 Oil Primary Control (0-Pre-purge/15 TFI/0- Post-purge. Interrupted Duty. Alarm Contacts) view more 
Oil Primary Control
NO PRE PURGE
NO POST-PURGE
15 SEC. TRIAL FOR IGNITION
INTERRUPTED DUTY
INCLUDES ALARM CONTACTS 
- Interrupted Duty Ignition Recycle on Flame Failure
- Serviceman Reset Protection ( Latch-up after three consecutive lockouts)
- Diagnostic LED's
- 15 Second Trial for Ignition (TFI)
- 1.3 Second Flame Failure response time (FFRT)
- Alarm Contacts
- Thermostat/aquastat Compatible
- SMC (Safety Monitoring Circuit) Technology
- Power Input (From Limit Circuit) 120 vac, 60 Hz, 9 VA
- Motor Load 10 FLA/60 LRA Ignitor Load 120 vac, 60 Hz, 500 VA Alarm Contacts 24 V, AC/DC, 2 A
- Operating Temperature Limits + 32°F to + 140°F
- Storage Temperature Limits -40°F to +185°F
- Thermostat Anticipator Current 0.2 A, AC Cad Cell Resistance with Flame R < 1500 OHMS
Hide Description
Does not ship to OH, United States
 8 In Stock 

 Oil Primary Control (15 Pre-purge/15 TFI/15 Post-Purge. Interrupted Duty. Alarm Contacts) view more 
Oil Primary Control 
15 Sec Pre-purge
15 Sec. Post-Purge
15 Sec. trial for Ignition
Interrupted Duty
Includes Alarm Contacts
Power Input (from limit circuit)............... 120VAC, 60Hz, 9VA 
Limit Circuit Input (black wire).......................120VAC, 60 Hz 
Motor Load....................................................10FLA, 60 LRA 
Ignitor Load ..................................... 120 VAC, 60Hz, 500 VA 
Alarm Contacts.............................................24V, AC/DC, 2A 
Operating Temperature Limits.................... +32°F to +140°F 
Storage Temperature Limits ........................ -40°F to +185°F 
Thermostat Anticipator Current...............................0.1A, AC 
CAD Cell Resistance (with flame)....................R<1500 ohms 
Agencies...............................UL Recognized (US & Canada)
Does not ship to OH, United States
 11 In Stock 

 Oil Primary Control (30 Pre-purge/15 TFI/30 Post-Purge. Interrupted Duty. Alarm Contacts) view more 
Oil Primary Control 
30 Sec Pre-purge
15 Sec. Post-Purge
30 Sec. trial for Ignition
Interrupted Duty
Includes Alarm Contacts
Power Input (from limit circuit)............... 120VAC, 60Hz, 9VA 
Limit Circuit Input (black wire).......................120VAC, 60 Hz 
Motor Load....................................................10FLA, 60 LRA 
Ignitor Load ..................................... 120 VAC, 60Hz, 500 VA 
Alarm Contacts.............................................24V, AC/DC, 2A 
Operating Temperature Limits.................... +32°F to +140°F 
Storage Temperature Limits ........................ -40°F to +185°F 
Thermostat Anticipator Current...............................0.1A, AC 
CAD Cell Resistance (with flame)....................R<1500 ohms 
Agencies...............................UL Recognized (US & Canada)
Does not ship to OH, United States
 1 In Stock 

 CARLIN UNIVERSAL OIL PRIMARY CONTROL view more 
- Replaces virtually any oil primary control
- Pinpoints cause of burner faults for fast, accurate repairs
- 3 different ignition options (Smart, Interrupted and Intermittent) • Last Fault Alert – Displays fault reason even if homeowner resets control
- Larger LCD Display – Straightforward fault messages with no codes to decipher
- Simple Setup – “Plug and Play” on your favorite application
- Recessed Wiring Terminals – Added wiring space in j-box
- Low Voltage Blocked Vent Contacts – Allows for easy connection
Does not ship to OH, United States
 2 In Stock 
 
 