Images are representations only.

CARLIN OIL PRIMARY CONTROLS

Brand: Carlin Combustion Technology, Inc
Does not ship to OH, United States
CARLIN OIL BURNER PRIMARY CONTROL 120V
CARLIN OIL BURNER PRIMARY CONTROL 120V
Models matching criteria: 6
CARLIN 60200
Oil Primary Control (0-Pre-Purge/15 TFI/0-Post-Purge. Interrupted Duty.) view more
Oil Primary Control 
NO PRE-PURGE
NO POST-PURGE
15 SEC TRIAL FOR IGNITION
INTERRUPTED DUTY. 
Does not have Alarm Contacts)
Does not ship to OH, United States
8 In Stock
CARLIN CONTROL 48245.png
OIL BURNER PRIMARY 0-Pre-Purge/0-Post-Purge 15 OR 45 SEC TFI view more
  • OIL BURNER PRIMARY  
  • NO PRE-PURGE
  • NO POST-PURGE
  • 15 OR 45 SECOND TRIAL FOR IGNITION
  • Intermittent Duty Ignition 
  • Red LED Lockout Indicator
  • Thermostat/aquastat Compatible SMC (Safety Monitoring Circuit) Technology
  • Power Input (From Limit Circuit) 120 vac, 60 Hz, 10 VA Motor Load 5 FLA/60 LRA Ignitor Load 120 vac, 60 Hz, 500 VA
  • Operating Temperature Limits + 32°F to + 140°F
  • Storage Temperature Limits -40°F to +185°F
  • Thermostat Anticipator Current 0.2 A, AC Cad Cell Resistance with Flame R < 1500 OHMS

48245 E Series Oil Primary Control (Optional 15 or 45 Sec. TFI. Constant/Intermittent Duty with Smart Ignition) Direct replacement for 3-wire primary controls (ex. Honeywell R8184G4009)

 

Does not ship to OH, United States
12 In Stock
CARLIN 60200
Oil Primary Control (0-Pre-purge/15 TFI/0- Post-purge. Interrupted Duty. Alarm Contacts) view more
Oil Primary Control
NO PRE PURGE
NO POST-PURGE
15 SEC. TRIAL FOR IGNITION
INTERRUPTED DUTY
INCLUDES ALARM CONTACTS 
  • Interrupted Duty Ignition Recycle on Flame Failure
  • Serviceman Reset Protection ( Latch-up after three consecutive lockouts)
  • Diagnostic LED's
  • 15 Second Trial for Ignition (TFI)
  • 1.3 Second Flame Failure response time (FFRT)
  • Alarm Contacts
  • Thermostat/aquastat Compatible
  • SMC (Safety Monitoring Circuit) Technology
  • Power Input (From Limit Circuit) 120 vac, 60 Hz, 9 VA
  • Motor Load 10 FLA/60 LRA Ignitor Load 120 vac, 60 Hz, 500 VA Alarm Contacts 24 V, AC/DC, 2 A
  • Operating Temperature Limits + 32°F to + 140°F
  • Storage Temperature Limits -40°F to +185°F
  • Thermostat Anticipator Current 0.2 A, AC Cad Cell Resistance with Flame R < 1500 OHMS
Hide Description
Does not ship to OH, United States
8 In Stock
CARLIN 60200
Oil Primary Control (15 Pre-purge/15 TFI/15 Post-Purge. Interrupted Duty. Alarm Contacts) view more
Oil Primary Control 
15 Sec Pre-purge
15 Sec. Post-Purge
15 Sec. trial for Ignition
Interrupted Duty
Includes Alarm Contacts
Power Input (from limit circuit)............... 120VAC, 60Hz, 9VA 
Limit Circuit Input (black wire).......................120VAC, 60 Hz 
Motor Load....................................................10FLA, 60 LRA 
Ignitor Load ..................................... 120 VAC, 60Hz, 500 VA 
Alarm Contacts.............................................24V, AC/DC, 2A 
Operating Temperature Limits.................... +32°F to +140°F 
Storage Temperature Limits ........................ -40°F to +185°F 
Thermostat Anticipator Current...............................0.1A, AC 
CAD Cell Resistance (with flame)....................R<1500 ohms 
Agencies...............................UL Recognized (US & Canada)
Does not ship to OH, United States
10 In Stock
CARLIN 60200
Oil Primary Control (30 Pre-purge/15 TFI/30 Post-Purge. Interrupted Duty. Alarm Contacts) view more
Oil Primary Control 
30 Sec Pre-purge
15 Sec. Post-Purge
30 Sec. trial for Ignition
Interrupted Duty
Includes Alarm Contacts
Power Input (from limit circuit)............... 120VAC, 60Hz, 9VA 
Limit Circuit Input (black wire).......................120VAC, 60 Hz 
Motor Load....................................................10FLA, 60 LRA 
Ignitor Load ..................................... 120 VAC, 60Hz, 500 VA 
Alarm Contacts.............................................24V, AC/DC, 2A 
Operating Temperature Limits.................... +32°F to +140°F 
Storage Temperature Limits ........................ -40°F to +185°F 
Thermostat Anticipator Current...............................0.1A, AC 
CAD Cell Resistance (with flame)....................R<1500 ohms 
Agencies...............................UL Recognized (US & Canada)
Does not ship to OH, United States
1 In Stock
70200
CARLIN UNIVERSAL OIL PRIMARY CONTROL view more
  • Replaces virtually any oil primary control 
  • Pinpoints cause of burner faults for fast, accurate repairs 
  • 3 different ignition options (Smart, Interrupted and Intermittent) • Last Fault Alert – Displays fault reason even if homeowner resets control
  • Larger LCD Display – Straightforward fault messages with no codes to decipher 
  • Simple Setup – “Plug and Play” on your favorite application 
  • Recessed Wiring Terminals – Added wiring space in j-box 
  • Low Voltage Blocked Vent Contacts – Allows for easy connection
Does not ship to OH, United States
16 In Stock

Applications

PRIMARY CONTROL FOR OIL BURNER 120V

Review this product and let us know your experiences

Write a Review