Images are representations only.

WALL HUNG GAS BOILER

Brand: Utica Boilers
Does not ship to OH, United States
  • 95% AFUE, ENERGY STAR® Certified
  • AI Control Technology, Auto Commissioning and Continuous Calibration functions optimize combustion and result in lower fuel costs. Control Panel features a backlit digital display that indicates boiler status, temperature, and diagnostics.
  • 6.9:1 Turndown Modulation Ratio in DHW Mode (MAC-115)
  • 7:1 Turndown Modulation Ratio in DHW Mode (MAC-150, MAC-205)
  • 5.6:1 Turndown Modulation Ratio in Heating Mode (MAH-100, MAC-115)
  • 5.7:1 Turndown Modulation Ratio in Heating Mode (MAH-125, MAC-150)
  • 5.5:1 Turndown Modulation Ratio in Heating Mode (MAH-165, MAC-205)
  • Flow Rate in DHW Mode:
  • 5.0 GPM @ 70° F rise (MAC-205)
  • 3.5 GPM @ 70° F rise (MAC-150)
  • 2.5 GPM @ 70° F rise (MAC-115)
  • Primary/Secondary LABOR SAVER™ Manifold Included
  • Heat Exchanger: 316L Stainless Steel Heat Exchanger and Burner. MAC-205, MAC-150 and MAC-115 are also equipped with a Stainless Steel Brazed Plate Heat Exchanger.
  • Additional Features: Assembled Boiler With Jacket, Induced Draft Fan, High Limit Sensors, 30 psi Relief Valve, Low Water Pressure Switch and, Temperature/Pressure Gauge.
  • Built in load matching Pump contributes to savings in electrical usage.
  • 95% AFUE, ENERGY STAR® Certified
  • AI Control Technology, Auto Commissioning and Continuous Calibration functions optimize combustion and result in lower fuel costs. Control Panel features a backlit digital display that indicates boiler status, temperature, and diagnostics.
  • 6.9:1 Turndown Modulation Ratio in DHW Mode (MAC-115)
  • 7:1 Turndown Modulation Ratio in DHW Mode (MAC-150, MAC-205)
  • 5.6:1 Turndown Modulation Ratio in Heating Mode (MAH-100, MAC-115)
  • 5.7:1 Turndown Modulation Ratio in Heating Mode (MAH-125, MAC-150)
  • 5.5:1 Turndown Modulation Ratio in Heating Mode (MAH-165, MAC-205)
  • Flow Rate in DHW Mode:
  • 5.0 GPM @ 70° F rise (MAC-205)
  • 3.5 GPM @ 70° F rise (MAC-150)
  • 2.5 GPM @ 70° F rise (MAC-115)
  • Primary/Secondary LABOR SAVER™ Manifold Included
  • Heat Exchanger: 316L Stainless Steel Heat Exchanger and Burner. MAC-205, MAC-150 and MAC-115 are also equipped with a Stainless Steel Brazed Plate Heat Exchanger.
  • Additional Features: Assembled Boiler With Jacket, Induced Draft Fan, High Limit Sensors, 30 psi Relief Valve, Low Water Pressure Switch and, Temperature/Pressure Gauge.
  • Built in load matching Pump contributes to savings in electrical usage.
Models matching criteria: 5
MAC IMAGE
WALL HUNG CONDENSING GAS COMBI BOILER-NAT OR LP view more
  • INPUT DHW MODE: 153 MBH
  • DHW MODE MIN: 22 MBH
  • FLOW RATE GPM: 3.5
  • CH MODE: 125 MBH
  • HEATING CAPACITY: 113 MBH
  • 95% AFUE
  • 4"/2" CONCENTRIC PIPING, 2',3" POLYPRO, OR 3" CPVC
  • HEIGHT: 30"
  • WIDTH: 17-3/4"
  • DEPTH: 13-9/16"
  • SYSTEM SUPPLY: 3/4"
  • DHW OUTLET: 1/2 COPPER SWEAT:
  • GAS CONNECTION: 3/4"
  • SUPPLY/RETURN BOILER-11/4" COPPER SWEAT (INLCUDES "LABOR SAVER MANIFOLD"
Does not ship to OH, United States
Out of Stock
MAC IMAGE
WALL HUNG CONDENSING GAS COMBI BOILER-NAT OR LP view more
  • INPUT DHW MODE: 205 MBH
  • DHW MODE MIN: 29.5 MBH
  • FLOW RATE GPM: 5.0
  • CH MODE: 164 MBH
  • CH MODE MIN: 29.5 MBH
  • HEATING CAPACITY: 153 MBH
  • 95% AFUE
  • 5"/3" CONCENTRIC PIPING, 2',3" POLYPRO, OR 3" CPVC
  • HEIGHT: 30"
  • WIDTH: 17-3/4"
  • DEPTH: 21-1/2"
  • SYSTEM SUPPLY: 1"
  • DHW OUTLET: 3/4:
  • GAS CONNECTION: 3/4"
  • SUPPLY/RETURN BOILER: 11/4" COPPER SWEAT (INCLUDES "LABOR SAVER" MANIFOLD)
Does not ship to OH, United States
Out of Stock
MAC IMAGE
WALL HUNG CONDENSING GAS BOILER, HEAT ONLY-NAT OR LP view more
  • CH  MODE: 125 MBH
  • CH MODE MIN: 22 MBH
  • HEATING CAPACITY 113 MBH
  • 95% AFUE
  • 4"/2" CONCENTRIC PIPING, 2',3" POLYPRO, OR 3" CPVC
  • GAS CONNECTION 3/4"
  • SUPPLY/RETURN BOILER: 11/4" COPPER SWEAT (INCLUDES "LABOR SAVER" MANIFOLD)
Does not ship to OH, United States
1 In Stock
MAC IMAGE.png
WALL HUNG CONDENSING GAS BOILER, HEAT ONLY-NAT OR LP view more
  • CH MODE: 164 MBH
  • CH MODE MIN: 29.5 MBH
  • 95% AFUE
  • 5"/3" CONCENTRIC PIPING, 2, 3" POLYPRO, OR 3" CPVC
  • HEIGHT: 30"
  • WIDTH: 17-3/4"
  • DEPTH: 21-1/2"
  • GAS CONNECTION: 3/4"
  • SUPPLY/RETURN BOILER: 11/4" COPPER SWEAT (INCLUDES "LABOR SAVER" MANIFOLD)
Does not ship to OH, United States
Out of Stock
Utica Condensing Only Floor Mounted Boiler (With Floor Mounted Stand) view more

UTICA CONDENSING HEAT ONLY 
FLOOR MOUNTED BOILER (Floor Mount Stand) 
125,000 BTU INPUT
113,000 BTU HEATING CAPACITY
22,000 BTU MINIMUM
95% AFUE. 

Does not ship to OH, United States
1 In Stock