Immersion Type Aquastat, Bulk Pack

Price
Request a Quote
Stock
In Stock
Does not ship to VA, United States

Specifications

Hazmat Information

  • UN 1294, TOLUENE, 3, II

Dimension

  • Insertion depth: 3 in.
  • Insertion depth: 76.2 mm

Temperature Range

  • Maximum: 40 °F above setpoint or 265 °F, which ever is lower.
  • Maximum: 22 °C above setpoint or 129.4 °C, which ever is lower.

Includes

  • Siphon Loop

Mounting

  • Mount using 1/4 in. NPT female threads or surface mount through base of case

Electrical Ratings

  • Millivolt - 0.25 A @ 0.25 to 12 Vdc; At Full Load - 8A @ 120 Vac: 4A @ 240 Vac; At Locked Rotor - 48A @ 120 Vac: 24A @ 240 Vac

Approvals, Underwriters Laboratories Inc.

  • UL Listed: -models with well, File No. MP466, Guide No. MBPR, -models less well, File No. MP466, Guide No. MBPR2

Approvals, American Gas Association

  • AGA Design Certified: Test Report 23-11B

Operating Temperature Range

  • 100 °F to 200 °F
  • 38 °C to 93 °C

Differential Temperature

  • 8 F
  • 4.4 C

Switching Action

  • Breaks contact on temperature rise to set point.

Insulation Depth

  • 1-1/2 in. to 3 in.
  • 38 mm to 76 mm
show more